Parameters
|
||||
|
Part name
|
Model
|
Specifications
|
||
|
Scanning frame
|
SM100
|
Scanning frame aperture: 700mm±10mm
Scanning frame rotation speed: 0.75s, 1.0s, 1.5s, 2.0s Scanning field of view: 430mm Type of Slip ring: contact slip ring |
||
|
High voltage generator
|
CT70PN32X5610
|
Tube voltage setting: 70~140kV
Tube current range: 10~300mA Nominal output power: 32kW |
||
|
Collimator
|
CMT-003
|
Half value layer:≥4.6mmAl
Equivalent aluminum equivalent thickness:2.3mmAl |
||
|
X-ray tube sleeve
|
B-240H
|
Nominal tube voltage: 140kV
Nominal anode input power: 29kW/48kW Maximum continuous heat dissipation of anode: 3.5kW Focus size: 0.7mm ×0.8mm 1.2mm ×1.4mm Anode rotation speed: 60Hz/180Hz Diameter of anode target surface (mm): 140mm Target angle: 7° Anode type: rotating anode Bearing type: mechanical bearing Quantity (pcs): 1 Fly focus (x to z offset): none The longest spiral scanning time: 100s Anode heat capacity:3.5MHU |
||
|
X-ray tube
|
GS-30722
|
|||
|
Detector
|
DET-003
|
Scintillation crystal material: GOS crystal
Pixel matrix: 704×16 Number of detectors: 11 Coverage (projected to the center of rotation): 430mm Pixel size (projected to the center of rotation) 1.25mm × 1.25mm Scanning angle: 0°/90° Scanning field of view: 430mm Axial scanning layer thickness: 1.25 mm ± 0.625 mm, 2.50 mm ± 1.0 mm, 5.00 mm ± 1.0 mm, 10.0 mm ± 1.0 mm; Spiral scanning layer thickness: 1.25 mm ± 0.625 mm, 2.50 mm ± 1.0 mm, 3.75 mm ± 1.0 mm, 5.00 mm ± 1.0 mm, 7.50 mm ± 1.0 mm, 10.0 mm ± 1.0 mm; Collimation combination: 16×1.25, 4×1.25; |
||
|
Diagnostic bed
|
ZC300
|
Z-axis positioning accuracy (mm): ≤±1mm
Speed: 0~150mm/s Vertical lifting range: ≥440mm Maximum load: 205kg |
||
|
Laser
|
M63AXSAXX-XX
|
Category: 2 types
Positioning accuracy: ±1mm Wavelength: 600~700nm Maximum output power: <1mW |
||
|
Console
CZ100 |
KH100
|
Control box:
Exposure control Bed motion control Intercom function |
||
|
/
|
Computer
The minimum configuration requirements are as follows CPU performance: the main frequency is not less than 2 GHz, the number of cores is not less than 2 cores Memory size: no less than 8GB Image storage capacity: no less than 850GB |
|||
|
/
|
Monitor
The minimum configuration requirements are as follows Screen resolution: 1920×1200 SXGA Number of displays size: 1*24 inches Type: LCD, color Contrast ratio: 1000:1 Preview |
|||
|
Computer image processing software
|
ScintVue
|
Release version: 1.0
|
||